• Home
  • News
  • About us
  • Data safety
    • Cookies usage policy
  • E-Shop
+371 67603399
English
  • Latviešu
  • Русский
  • Lithuanian
  • Estonian
  • All for wood
  • Building materials
  • Heat transfer fluids
  • Ion heating boilers
  • Thermodynamic systems
  • Contacts
  • +371 67603399
    English
    • Latviešu
    • Русский
    • Lithuanian
    • Estonian
  • About heaters
    • News
    • Strong points of STAFOR ion boilers
    • Videos about ion boilers (heaters)
    • COP - Coefficient of Performance
    • European Union Directives
    • Gallery
  • Ion heating boilers
    • Ion boilers sets
      • Ion boiler STAFOR 3-5
      • Ion boiler STAFOR 5-10
      • Ion boiler STAFOR 6-9
      • Ion boiler STAFOR 10-20
      • Ion boiler STAFOR 20-30
    • Ion boiler with built-in heat exchanger
      • Ion boiler with heat exchanger STAFOR 6-9HE
      • Ion boiler with heat exchanger STAFOR 10-20HE
      • Ion boiler with heat exchanger STAFOR 20-30HE
    • Special ion heating boilers and accessories
      • Built-in tank ion heater STAFOR 5-10SI
      • Heat carrier buffer tank for ion boilers in primary circuit
  • Ion boilers control automatic
    • Control panel sets
      • For ion boiler (heater) 3-5
      • For ion boiler (heater) 5-10
      • For ion boiler (heater) 6-9
      • For ion boiler (heater) 10-20
      • For ion boiler (heater) 20-30
    • Additional equipment for ion boilers control panels
      • Digital room thermostat-programmator (C55)
      • Wireless set for week programmator (C55)
      • Simistor maximal power controller STAFOR MPC
      • Mechanical thermostat
      • Emergency thermostat
      • GSM thermostat-programmer for ion boiler
      • Smart thermostat for ion heater
  • Heat carrier for ion boilers
  • How to buy
  • Support
    • FAQ
      • About ion heating boilers
      • About operating costs
      • About installation
      • About control automatic
    • Ion boiler regulation instruction
    • Ion boiler in small circuit
    • Documents

About ion boiler control panels and automation

Why circuit breaker is included in control panel?

Circuit breaker performs several functions:
  • Protection from short circuit;
  • Protection of ion boiler from work mode that exceeds those stated by boilers construction;
  • Switchin ON/OFF of boiler in manual mode.
Ion boiler (heater) operation without boiler and/or circulation pump protection circuit breaker, or a circuit breaker which nominal does not comply with the technical characteristics, or which is out of order is strictly prohibited.​

Ion boiler control panel have anti freezing mode?

Control panel set includes digital thermostat-programmer C55, which can be programmed so that it maintains air temperature in room +5°С to protect the system from freezing, at the time when normal heating mode is switched OFF. Additionally to it, ion boilers heat carrier (coolant) STATERM EKO E40 does not freeze till -40°С.

Which batteries week thermostat - programmer (C55) need and how long they last?

Thermostat-programmer (C55) works from two type AA 1.5V standard batteries. Work life - up to 2 years. When batteries need to be changed, appropriate symbol on the programmer screen will appear. During battery change programs saved on C55 will not be lost.