• Home
  • News
  • About us
  • Data safety
    • Cookies usage policy
  • E-Shop
+371 67603399
English
  • Latviešu
  • Русский
  • Lithuanian
  • Estonian
  • All for wood
  • Building materials
  • Heat transfer fluids
  • Ion heating boilers
  • Thermodynamic systems
  • Contacts
  • +371 67603399
    English
    • Latviešu
    • Русский
    • Lithuanian
    • Estonian
  • About heaters
    • News
    • Strong points of STAFOR ion boilers
    • Videos about ion boilers (heaters)
    • COP - Coefficient of Performance
    • European Union Directives
    • Gallery
  • Ion heating boilers
    • Ion boilers sets
      • Ion boiler STAFOR 3-5
      • Ion boiler STAFOR 5-10
      • Ion boiler STAFOR 6-9
      • Ion boiler STAFOR 10-20
      • Ion boiler STAFOR 20-30
    • Ion boiler with built-in heat exchanger
      • Ion boiler with heat exchanger STAFOR 6-9HE
      • Ion boiler with heat exchanger STAFOR 10-20HE
      • Ion boiler with heat exchanger STAFOR 20-30HE
    • Special ion heating boilers and accessories
      • Built-in tank ion heater STAFOR 5-10SI
      • Heat carrier buffer tank for ion boilers in primary circuit
  • Ion boilers control automatic
    • Control panel sets
      • For ion boiler (heater) 3-5
      • For ion boiler (heater) 5-10
      • For ion boiler (heater) 6-9
      • For ion boiler (heater) 10-20
      • For ion boiler (heater) 20-30
    • Additional equipment for ion boilers control panels
      • Digital room thermostat-programmator (C55)
      • Wireless set for week programmator (C55)
      • Simistor maximal power controller STAFOR MPC
      • Mechanical thermostat
      • Emergency thermostat
      • GSM thermostat-programmer for ion boiler
      • Smart thermostat for ion heater
  • Heat carrier for ion boilers
  • How to buy
  • Support
    • FAQ
      • About ion heating boilers
      • About operating costs
      • About installation
      • About control automatic
    • Ion boiler regulation instruction
    • Ion boiler in small circuit
    • Documents

Ion heater STAFOR installation in small circuit

Ion heating boiler can be installed in small circuit to avoid filling complete heating system with heat carrier STATERM EKO E40. This can be needed if ion boiler must be installed on old heating system where heat carrier leakage is possible or brand new heating system with large volume, etc.

In such connections there is essential condition - appropriate small (primary) circuit volume must be ensured. To ensure neccessary volume any kind of tank can be used. We recommend to use STAFOR buffer tank. If minimal primary circuit volume cannot be ensured with only one tank, two or more can be used. 
 
Minimal heat carrier (coolant) volume in primary circuit is necessary due to few reasons. First of them is very high speed of liquid heating in ion heater, usually it takes only few seconds and there is too less of time to transfer heat thru coil or plate heat exchanger and as result heat carrier boils up. Second reason - primary circuit must have some heat inertia and time for heat carrier to restore its properties. This time is needed because heating in ion boiler happens due to heat carriers (coolant) properties and they are affected during this process.

Recommended connection schema for small (primary) circuits and its minimal volume for each ion boiler model, depending on boiler power showed in file.

Ion heating boiler connection schema in small circuit

0.91Mb
  • Ion boiler in small circuit with STAFOR buffer Ion boiler in small circuit with STAFOR buffer
  • Ion boiler in small circuit with STAFOR buffer Ion boiler in small circuit with STAFOR buffer
  • Ion boiler in small circuit with STAFOR buffer Ion boiler in small circuit with STAFOR buffer
  • Ion boiler in small circuit with STAFOR buffer Ion boiler in small circuit with STAFOR buffer